Follett 110 Series User Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
10. Apply a thick bead, approximately. 6mm (1/4")
diameter, of NSF listed silicone sealant (Dow-
Corning RTV-732 or equivalent) 6mm (1/4") inside
marked outline of dispenser.
11. Carefully position dispenser on counter.
12. Remove four screws securing splash panel to front
of dispenser and gently lay splash panel on counter.
(Water line to solenoid valve can be disconnected
from water inlet valve by pushing on ring at end of
inlet fitting while pulling on tubing.)
13. Secure dispenser to counter with four 3/8" bolts
(supplied by others).
14. Smooth excess sealant around outside of dispenser.
15. Run water supply line from back of dispenser
through utility knock-out (Figs. 4, 5) or up through
counter cut-out. Connect water supply line to 3/8"
FPT, (Fig. 3J) fitting on utility flange at bottom of
dispenser.
16. Remove 3/4" drain connection plug from either fitting
at rear of dispenser, (Fig. 1K) or internal fitting, (Fig.
3L), as appropriate. Connect and run a dedicated
drain line to wall or floor drain. An air break should
be provided.
If dispenser is equipped with a top mount, water-
cooled icemaker complete steps 17 through 20.
If equipped with a top mount,
air-cooled icemaker proceed to step 21.
17. Connect icemaker water supply line to 3/8" FPT
water inlet, (Fig. 4M).
18. Connect icemaker drain line to 3/4 MPT drain
connection (Fig, 4N).
19. If icemaker is water-cooled, connect water-cooled
condenser supply line to 3/8" FPT condenser fitting
on back of dispenser (Fig. 4R).
Note: Do not run condenser supply water through
icemaker water filter system.
20. Connect condenser drain line to 3/8" FPT fitting on
back of dispenser (Fig. 4P).
Important: Do not connect condenser drain line to
any other drain lines.
21. Proceed with either Satellite-fill or top-mounted
icemaker connection instructions, as appropriate.
9
Fig. 4 – Rear connections, countertop models with
integral icemakers
Fig. 5 – Rear connections, countertop models with
Satellite-fill icemakers
access panel
access panel
(M) 3/8" FPT
icemaker water inlet
(R) 3/8" FPT condenser inlet
(water-cooled only)
(P) 3/8" FPT
condenser outlet
(water-cooled only)
(N) 3/4" MPT
icemaker drain
(H) utility knock-out
(G) ice transport tube knock-out
(H) utility knock-out
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 27 28

Comments to this Manuals

No comments